TECHNICAL SPECIFICATIONS
| Machine code | TPS1125 |
|---|
| General frame envelope | Approximately 8.73 × 5.28 × 11.00 m |
|---|
| Cited two-effect package envelope | Approximately 8.00 × 5.00 × 7.20 m |
|---|
| Cold Break reference input | Approximately 500 t of fresh tomatoes per 24 h at 5 °Bx feed and 25 °Bx paste |
|---|
| Product-contact construction | AISI 304 with argon-welded tube connections and food-grade seals |
|---|
| Standard listed | 761 |
|---|
Paste effect
Vertical live-steam exchanger with sight glass, automatic level control, CIP, temperature indication, vacuum sensor and circulation impeller. A 160 kW, 1,000 rpm centrifugal recirculation drive uses a Rotex coupling and Fuji inverter for flow regulation.
Tomato-juice effect
Vertical exchanger powered by recovered vapour, sight glass, automatic level control, CIP, temperature indication and vacuum sensor. The recirculation drive is rated 110 kW at 1,000 rpm with a Rotex coupling. A 3 kW, 1,450 rpm centrifugal pump with KB coupling transfers product from the juice effect to the paste effect.
Support and access
The general design describes size-18 beams or channels, 180 mm post sections and cross-bracing. The cited package uses size-24 beams, a 5 × 8 m frame approximately 7.2 m high, eight 200 mm steel posts, bracing and anti-rust and finish coats. It includes stairs, railings and overhead lifting for exchanger removal.
Steam and condensate
6-inch stainless pneumatic steam ball valve with control, condensate drain and trap, AISI 304 condenser, Pumpiran condensate pump, level control valve, auxiliary condenser and AISI 304 feed tank made of 4 mm plate. The auxiliary Pumpiran pump uses a 5.5 kW, 1,450 rpm drive with KB coupling. The main condenser uses a 55 kW, 1,000 rpm drive with Rotex coupling, circulating-water temperature sensors and vacuum sensing.
Vacuum and paste discharge
Model 750 water-ring vacuum pump with a 15 kW, 1,450 rpm drive and KB coupling. A progressive-cavity discharge pump uses an 11 kW, 900 rpm drive with Fuji inverter. Thermometers, vacuum gauges and pressure gauges support monitoring.
Controls
Siemens or comparable PLC and I/O, 15-inch Delta touchscreen or 21-inch industrial PC, Siemens or Inor temperature sensors or equivalents, European or Japanese level sensors, AISI 316 inter-effect valve, Siemens/Noark electrical gear or equivalents, Fuji/Delta drives and Keystone or Yoshitake on/off valves in the documented build.
Utilities for the cited build
Approximately 250 A during operation, 450 m³/h circulation water at 30–35 °C, or 10 m³/h tower make-up/overflow as specified for the cooling-tower option. Dry steam demand is 9,000 kg/h at 6 atmospheres, with 10 atmospheres at the boiler. Compressed air is required for pneumatic valves.